Configuring RRC-1258
for
Alinco DX-SR8, detached panel
(mode=12)
|
||||||||||||||||||||||||||||||||||||||||||||||||
|
Before you can use your
RRC-1258MkII you must configure both the hardware (strappings) and the
software settings. They units will have the IP addresses
192.168.0.227 (control) and 192.168.0.228 (radio) when shipped. The net mask is
255.255.255.0. The configuration is easiest done via the web interface. Be
aware of that your PC must be in the same net eg. have a IP-number between
192.168.0.2 and 192.168.0.254 and it must not be the same as the RRC:s. If
the default IP-addresses of the RRC is not fitting into your network please
use the RRC-Manager ( via USB) to change their IP:s see
Start up settings. It's convenient to use DHCP at
the control RRC but wait to active DHCP until everything is setup and
working. Configuration of the radio specific parameters (Control-RRC-1258MkII ) via internal web server Open your web browser and write the IP address corresponding to the RRC-1258MkII you want to configure. Click on the "Radio Settings" link to left. You will now see a new web page where the existing parameter settings is shown. Edit the parameters you need to change and then click on "submit". The new settings will now be save in the non volatile memory. When you have done all changes need on the different pages the click on the "Apply Changes " button and the RRC will restart with the new settings in place. Down below is the parameters which is important for the TS-480 described. For the other parameters check the "Common configs" page.
Configuration of the radio specific parameters (Radio-RRC-1258MkII ) via internal web server Open your web browser and write the IP address corresponding to the RRC-1258MkII you want to configure. Click on the "Radio Settings" link to left. You will now see a new web page where the existing parameter settings is shown. Edit the parameters you need to change and then click on "submit". The new settings will now be save in the non volatile memory. When you have done all changes need on the different pages the click on the "Apply Changes " button and the RRC will restart with the new settings in place. Down below is the parameters which is important for the TS-480 described. For the other parameters check the "Common configs" page.
|